新闻咨询

防爆正压柜结构特点原理

防爆正压柜适用于石油化工、海上钻井平台、冶金、医药、轻工、纺织、食品、生物工程、航天航空工程以及军事设施等工厂中,具有ⅡA、ⅡB、ⅡC类T1~T4爆炸性气体或蒸气环境;海拔高度不超过2000米;25℃时,相对湿度95%以下;工作环境温度-20℃~+40℃之间。可根据用户要求安装各种普通的检测仪表、分析仪表、显示仪表、变压器、软启动器、变频器、微电脑触摸屏以及普通电器元件,对用户内装电器元件基本不受限制。

配电(dian)柜(ju)由柜(ju)体、自控系(xi)统(tong)(tong)(tong)、布气系(xi)统(tong)(tong)(tong)、报警系(xi)统(tong)(tong)(tong)、配电(dian)系(xi)统(tong)(tong)(tong)组成;正压腔内装部(bu)分控制系(xi)统(tong)(tong)(tong)的防(fang)爆(bao)元件及用(yong)户的配电(dian)系(xi)统(tong)(tong)(tong)元件。

防爆正压柜采用Q235钢板焊接而成,对其各接合面都经过了特殊的密封处理。

防爆(bao)正压(ya)柜进气方(fang)式为通(tong)风型,即不间断连续供(gong)气,正压(ya)腔内装元件(jian)的(de)工作热量(liang)可(ke)随气路带走,具有很好的(de)散热效果。

本产品引用GB3836.1-2000 ,GB3836.5-2004以及(ji)相关标准设(she)计、制造(zao)、检验。

防爆正压柜的工(gong)作原理(li)

配电柜在自动(dong)控制系统的(de)控制下(xia),通(tong)入保(bao)(bao)护气体,正(zheng)压(ya)(ya)(ya)腔(qiang)内(nei)压(ya)(ya)(ya)力高(gao)于正(zheng)压(ya)(ya)(ya)腔(qiang)外(wai)的(de)压(ya)(ya)(ya)力,形成微正(zheng)压(ya)(ya)(ya)的(de)安(an)全小环境,从而阻止(zhi)了可燃性危险气体进入正(zheng)压(ya)(ya)(ya)腔(qiang)内(nei),保(bao)(bao)证内(nei)装普通(tong)仪表和电器元(yuan)件的(de)安(an)全运行。

自动(dong)控制系统(tong)主要完成(cheng)手动(dong)换(huan)气(qi)、补(bu)气(qi)、超高压(ya)(ya)自动(dong)报警和排气(qi)、欠压(ya)(ya)报警、低(di)压(ya)(ya)联锁(suo)断电(dian)等系列功能(neng)。(本配(pei)电(dian)柜具有低(di)压(ya)(ya)联锁(suo)功能(neng),低(di)于规(gui)定的气(qi)压(ya)(ya)值(zhi)(50Pa)时,自动(dong)切断进入正(zheng)压(ya)(ya)腔的用户配(pei)电(dian)电(dian)源(yuan))

防爆正压柜的安(an)装

一、柜体安装

1、柜(ju)体的(de)安装位置:户内或户外有棚(peng)顶(ding),无明显震动平坦的(de)地方(fang)。

2、本(ben)(ben)产品安装(zhuang)方式为落地(di)式和壁挂式,本(ben)(ben)柜设(she)置了(le)专(zhuan)用于固定的安装(zhuang)孔(kong),具(ju)体参数(shu)详见技(ji)术(shu)附件或(huo)产品实物。

3、布线方式为电(dian)缆布线,用户(hu)电(dian)缆结构(gou)可参考相关国家标(biao)准(zhun)和行业(ye)标(biao)准(zhun),并结合本柜的结构(gou)要(yao)求进行设(she)计、施工。

4、搬运时注意,本产品(pin)严禁大幅(fu)度倾斜(xie),倾斜(xie)度不大于100。

5、本产(chan)品(pin)在运输(shu)、安装定位时,严禁采用(yong)撬、锤等方式(shi)进行搬动(dong)。否则(ze),可(ke)能影响产(chan)品(pin)的密封(feng)性(xing)能,导致(zhi)本产(chan)品(pin)无(wu)法正(zheng)常运行。

6、本产品设置(zhi)(zhi)了进(jin)气(qi)(qi)(qi)口(kou)(kou)和排(pai)气(qi)(qi)(qi)口(kou)(kou),供用(yong)户接管(guan)(guan)。用(yong)户须(xu)按“气(qi)(qi)(qi)路管(guan)(guan)道布置(zhi)(zhi)图”布置(zhi)(zhi)进(jin)气(qi)(qi)(qi)管(guan)(guan)道,排(pai)气(qi)(qi)(qi)口(kou)(kou)经过(guo)防火(huo)阀后在现场排(pai)放或引至安全(quan)区(qu)域(yu)排(pai)放,用(yong)户现场须(xu)提供进(jin)气(qi)(qi)(qi)气(qi)(qi)(qi)源(yuan)(保(bao)护(hu)(hu)气(qi)(qi)(qi)体),气(qi)(qi)(qi)源(yuan)压力一(yi)般控制在0.2-0.6MPa,进(jin)气(qi)(qi)(qi)气(qi)(qi)(qi)源(yuan)为净(jing)化(hua)空气(qi)(qi)(qi)(如:仪(yi)表风)或氮气(qi)(qi)(qi),(注意(yi):在密闭的操(cao)作室里,要谨(jin)慎使用(yong)氮气(qi)(qi)(qi)作为保(bao)护(hu)(hu)气(qi)(qi)(qi)体,若必须(xu)使用(yong)氮气(qi)(qi)(qi)作保(bao)护(hu)(hu)气(qi)(qi)(qi)体,请注意(yi)现场通(tong)风,以确(que)保(bao)人(ren)身(shen)安全(quan))。

7、由于内(nei)装工控(kong)电(dian)器(qi)(qi)、触(chu)摸屏等精(jing)密电(dian)器(qi)(qi),气(qi)源进口(kou)处需加装干燥过滤器(qi)(qi),以确保气(qi)源为干燥清(qing)洁(jie)的(de)空气(qi),否则(ze)会(hui)影响电(dian)器(qi)(qi)的(de)使用寿命。

8、严禁(jin)进(jin)气(qi)气(qi)源为爆(bao)炸性混(hun)合气(qi)体!!

二、用户元件的安(an)装

1、由(you)于内装配电系统(tong)元件由(you)用(yong)户(hu)自行(xing)调(diao)整,因此,用(yong)户(hu)必须(xu)在安全(quan)区内进(jin)行(xing)设定、调(diao)试。

2、不得撤拆(chai)面板上的电器元件,以免影响柜体的气密(mi)性能。

三、 电气安装

1、本(ben)产(chan)品必须由专业电工,进行操(cao)作。

2、用户按我公司提供(gong)的电器系统图、接线图、端子图等技术文件(jian),结合产品实际情(qing)况逐一对应进行接线。

3、接(jie)线时,请(qing)注意各进(jin)出(chu)电缆的(de)(de)密(mi)封性(xing)(严禁(jin)将通头(tou)中的(de)(de)密(mi)封圈弃之不用),并视各电缆的(de)(de)松紧程度,用防(fang)爆胶泥作(zuo)适当的(de)(de)密(mi)封处理。

4、用(yong)户的(de)接线、调试完后,将(jiang)各门关(guan)闭(bi)时,一定要保(bao)证(zheng)其密(mi)封性能。

5、本柜体必须按要求(qiu)将接地线接到专用接地螺丝(si)上。

防爆正压柜的调(diao)试

本产品出厂时,正(zheng)压自控部分已经过调(diao)试(shi),但用户在具体使(shi)用时,仍须根(gen)据现(xian)场情况重新调(diao)试(shi)后再使(shi)用。

返回顶部按钮